Automation and digital product integration providerFV5-U3 Series Full-featured Servo FV5-E Series Direct-Drive Servo FV5-R Series Rotary-Type Servo FV5L Series Gantry-Double-Drive Servo FV3S Series Rotary-Type Servo FV3 Series Rotary-Type Servo FD5 Series Low-Voltage DC Servo High-Voltage AC Servo Motor Low-Voltage DC Servo Motor
-
Automation and digital product integration providerPackaging Industry Electronic Equipment 3C Equipment Semiconductor Industry Machine Tool Industry Photovoltaic Equipment Lithium Battery Equipment SCADA
-
Automation and digital product integration provider
-
Automation and digital product integration provider
FD5 Series
Low-Voltage DC Servo
Product Description
FD5 Low Voltage Servo Driver


Multiple Magnetic Pole Configurations

Supports Rotary and Direct Drive Motors

12-110VDC Power Supply
Specification
| FD5-*1-64* | FD5-*1-N6410 | FD5-*1-N6406 | FD5-*1-N6403 | FD5-*1-P6410 | FD5-*1-P6406 | FD5-*1-P6403 | ||
| Power Supply | Main loop power input | 12-64VDC (When only the main circuit is input, the drive can work normally, but it cannot be powered off the main circuit alone.And keep the drive in a communicable state) |
||||||
| Control loop power input | 12-64VDC (When only the control power is input, the drive can be powered on self-test, communication, etc., but cannot be enabled) |
|||||||
| Rated current (A)(Arms) | 10.0 | 6.0 | 3.0 | 10.0 | 6.0 | 3.0 | ||
| Maximun current(Arms) | 25.0 | 16.9 | 9.0 | 25.0 | 16.9 | 9.0 | ||
| Control mode | Motor | Motor type | Low voltage DDR motor, low voltage DDL motor, voice coil motor, low voltage rotary servo motor | |||||
| Magnetic pole identification method |
Low voltage DDR motor, low voltage DDL motor, voice coil motor, low voltage rotary servo motor | |||||||
| Automatic configuration | Support communication encoder power-on automatically read, configure motor parameters; Support independent encoder and third-party encoder switching; Supports phase sequence identification |
|||||||
| Operation mode | Optional mode | Torque mode, speed mode, position mode, (open/closed loop) force control mode | ||||||
| Torque control | Torque control bandwidth | 4.5K | ||||||
| Command source | Analog, EtherCAT, internal command | |||||||
| Current control accuracy | ±0.5%Rated output current | |||||||
| Speed control | Speed control bandwidth | 3K | ||||||
| Internal speed control refresh cycle |
16K | |||||||
| Control method | PI adjustment, torque feedforward, friction compensation, loop filtering, etc | |||||||
| Command source | Analog, Ethercat, internal multiple speed | |||||||
| Position control | The internal position controls the refresh cycle |
4K | ||||||
| Control method | Proportional adjustment, speed feedforward, command smoothing, etc | |||||||
| Command source | Pulse, EtherCAT, internal multisegment position | |||||||
| IO | AI | High precision AI | 1 channel, ±10VDC differential, resolution 16bit; Can be used for closed loop force control | |||||
| DI | Standard DI | 3-channel fast DI (P-type machine is 4 channels), directly connected to FPGA, photoelectric isolation, support NPN/PNP mode |
||||||
| High speed DI | 2 ultra-high speed DI, directly connected to FGPA, photoelectric isolation, support NPN/PNP mode | |||||||
| DO | Standard DO | 4-channel fast DO (P-type machine for 4), directly connected to FPGA, photoelectric isolation, NPN, maximum load 50mA |
||||||
| Pulse & Direction | When * is P, P type machine, P type machine support pulse signal input control (including differential form, OC form); Maximum input frequency 4MHz (OC form is 200K) |
|||||||
| Communication Interface |
EtherCAT communication | When * is N, N type machine, N type machine support EtherCAT communication control, minimum communication cycle 250us |
||||||
| Background debugging communication port | 1 USB Type C port, used for software debugging of the drive | |||||||
| RS485 communication port | When it is a P-type machine, 1: n communication up to 31 axes can be performed | |||||||
| Encoder (Motor Feedback Signal) Interface |
Communication type coding port | FD5-U series: RS485, support Tamagawa protocol, FLEXEM protocol, BISS C protocol; Maximum baud rate 4M, FD5-R series: RS485, support Tamagawa protocol, Maximum baud rate 4M | ||||||
| Dart line differential encoder port | ABZ, Maximum input frequency 5MHz; Can be used as a second encoder input for full closed loop applications; R series without the second interface |
|||||||
| Hall port | Single-ended NPN mode | |||||||
| Motor temperature sensor interface | Supported, thermistor PTC/NTC; R series without the PTC/NTC | |||||||
| Status Indicator | STA1_LED | Indicates the operating status of the drive | ||||||
| STA2_LED | Indicates drive failure status | |||||||
| Protection function |
Protection function | Input voltage undervoltage and overvoltage, driver overcurrent, overload, input short circuit to the ground protection, motor overload, high temperature protection, overrange,The position deviation is too large, the second encoder is missing, the car protection, the main circuit self-diagnosis of power-on, etc |
||||||
| Meet certificate standard | Under way | |||||||
| Environmental requirement | Environment | Ambient temperature | Operating temperature: 0-55℃: Storage temperature : -20-85℃ | |||||
| Ambient humidity | Ambient humidity:10-90% | |||||||
| Shock resistance | Shock: 1.0g | |||||||
| Altitude | Altitude: < 2000m | |||||||
| Pollution level | PD2 | |||||||
| Prohibited working environments |
Working environment with corrosive or combustible gases, chemicals or oily water, iron and salt containing dust |
|||||||
| Protection level | IP20 | |||||||
| Size | 57.5*75.5*25.4mm | |||||||
Related Products
COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
These cookies are necessary for basic functions such as payment. Standard cookies cannot be turned off and do not store any of your information.
These cookies collect information, such as how many people are using our site or which pages are popular, to help us improve the customer experience. Turning these cookies off will mean we can't collect information to improve your experience.
These cookies enable the website to provide enhanced functionality and personalization. They may be set by us or by third-party providers whose services we have added to our pages. If you do not allow these cookies, some or all of these services may not function properly.
These cookies help us understand what you are interested in so that we can show you relevant advertising on other websites. Turning these cookies off will mean we are unable to show you any personalized advertising.